TABLE 2

Blood gas and nocturnal gas exchange parameters at baseline situation and while using noninvasive ventilation (NIV) in NIV-group patients

BaselineUsing NIVp-value
PaO2 mmHg74.32±11.9584.06±11.42<0.001
PaCO2 mmHg50.34±8.6842.11±4.32<0.001
%sleepSpO2<9030.96±28.74%1.50±3.5%<0.001
SpO2mean91.68±3.03%95.56±1.50%<0.001
SpO2min79.76±9.30%92.41±3.39%<0.001

Data are presented as mean±sd unless otherwise stated. PaO2: arterial oxygen tension; PaCO2: arterial carbon dioxide tension; %sleepSpO2<90: time spent with oxygen saturation measured by pulse oximetry (SpO2) <90%; SpO2mean: mean SpO2; SpO2min: minimum SpO2.