Skip to main content

Main menu

  • Home
  • Current issue
  • Early View
  • Archive
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • COVID-19 submission information
    • Institutional open access agreements
    • Peer reviewer login
  • Alerts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • Early View
  • Archive
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • COVID-19 submission information
    • Institutional open access agreements
    • Peer reviewer login
  • Alerts
  • Subscriptions

Soluble urokinase plasminogen activator receptor for the prediction of ventilator-associated pneumonia

Pouline M. van Oort, Lieuwe D. Bos, Pedro Póvoa, Paula Ramirez, Antoni Torres, Antonio Artigas, Marcus J. Schultz, Ignacio Martin-Loeches on behalf of the BioVAP study
ERJ Open Research 2019 5: 00212-2018; DOI: 10.1183/23120541.00212-2018
Pouline M. van Oort
1Dept of Intensive Care, Amsterdam UMC, Academic Medical Centre, Amsterdam, The Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Pouline M. van Oort
  • For correspondence: p.m.vanoort@amc.uva.nl
Lieuwe D. Bos
1Dept of Intensive Care, Amsterdam UMC, Academic Medical Centre, Amsterdam, The Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Lieuwe D. Bos
Pedro Póvoa
2Polyvalent Intensive Care Unit, São Francisco Xavier Hospital, Centro Hospitalar de Lisboa Ocidental, Lisbon, Portugal
3NOVA Medical School, New University of Lisbon, Lisbon, Portugal
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paula Ramirez
4Respiratory Disease Dept, Hospital Clínici Provincial de Barcelona, IDIBAPS, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Antoni Torres
5Intensive Care Unit, University Hospital La Fe, Valencia, Spain
6CIBER de Enfermedades Respiratorias, Centro de Investigación Biomédica en Red, Madrid, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Antonio Artigas
6CIBER de Enfermedades Respiratorias, Centro de Investigación Biomédica en Red, Madrid, Spain
7Critical Care Dept, Corporacion Sanitaria Universitaria Parc Tauli, Autonomous University of Barcelona, Sabadell, Spain
8Critical Care Dept, Sagrado Corazon-General de Catalunya University Hospitals, Quiron Salud-IDC, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marcus J. Schultz
1Dept of Intensive Care, Amsterdam UMC, Academic Medical Centre, Amsterdam, The Netherlands
9Mahidol-Oxford Tropical Medicine Research Unit (MORU), Mahidol University, Bangkok, Thailand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ignacio Martin-Loeches
6CIBER de Enfermedades Respiratorias, Centro de Investigación Biomédica en Red, Madrid, Spain
10Dept of Clinical Medicine, St James's University Hospital, Dublin, Ireland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Introduction Diagnosing ventilator-associated pneumonia (VAP) remains challenging. Soluble urokinase plasminogen activator receptor (suPAR) has prognostic value in critically ill patients with systemic infection. We hypothesised that plasma suPAR levels accurately predict development of VAP.

Methods This observational, multicentre, prospective cohort study compared patients at risk for VAP with a control group. Plasma and tracheal aspirate samples were collected. Plasma suPAR levels were measured on the day of diagnosis and 3 days before diagnosis.

Results The study included 24 VAP patients and 19 control patients. The suPAR concentration measured 3 days before diagnosis was significantly increased in VAP patients versus matched samples of control patients (area under the receiver operating characteristic curve (AUC) 0.68, 95% CI 0.52–1.00; p=0.04). Similar results were found on the day of diagnosis (AUC 0.77, 95% CI 0.6–0.93; p=0.01). Plasma suPAR was significantly higher in deceased patients (AUC 0.79, 95% CI 0.57–1.00; p<0.001). Combining suPAR with the Clinical Pulmonary Infection Score, C-reactive protein and/or procalcitonin led to a significantly increased discriminative accuracy for predicting VAP and an increased specificity.

Conclusions suPAR can be used to diagnose VAP with a fair diagnostic accuracy and has a moderate prognostic accuracy to be used in critically ill intensive care unit patients. Its performance improves when added to other clinically available biomarkers (C-reactive protein and procalcitonin) or scoring systems (Clinical Pulmonary Infection Score and Sepsis-related Organ Failure Assessment).

Abstract

suPAR can be used to diagnose VAP with a fair diagnostic accuracy and has a moderate prognostic accuracy to be used in critically ill ICU patients http://ow.ly/ubmf30nIgZO

Introduction

Ventilator-associated pneumonia (VAP) is accountable for approximately one-third of nosocomial pneumonia cases [1], associated with a longer intensive care unit (ICU) and hospital length of stay (LOS), and increased healthcare costs [2]. VAP is associated with significant mortality [3, 4], excess morbidity [5] and an increased duration of mechanical ventilation [1, 6].

Due to the absence of a clinically available gold standard, the diagnosis of VAP remains challenging. The clinician has to rely on clinical parameters and radiological, laboratory and microbiological results [7], which may take hours to days to become available. A quicker predictive test is urgently needed, enabling a more accurate prediction of pneumonia and thus limiting antimicrobial misuse.

Multiple biomarkers, measured in serum and in bronchoalveolar lavage fluid (BALF), have been investigated for their diagnostic value in infections, e.g. the soluble triggering receptor expressed on myeloid cells sTREM-1 [8], interleukin (IL)-1β and IL-8 [9–11], C-reactive protein (CRP), and procalcitonin (PCT) [12, 13]. As yet, none of these biomarkers have been proven to have sufficient diagnostic or prognostic quality to be used in patients receiving antibiotic treatment for VAP [1]. Soluble urokinase plasminogen activator receptor (suPAR) has become of interest as an inflammatory biomarker that seems to positively correlate with the activity of the immune system and has been shown to have prognostic value in critically ill patients with systemic infection in terms of mortality prediction [14, 15]. In patients with acute respiratory distress syndrome, significantly higher suPAR plasma levels were found with increasing disease severity [16]. In critically ill patients, higher plasma suPAR levels were associated with longer duration of mechanical ventilation and increased ICU LOS [17], a higher incidence rate of readmission, and an increased mortality rate [18, 19]. In VAP and sepsis patients, suPAR has been shown to be an independent predictor of an unfavourable outcome [20].

We hypothesised that suPAR measured in plasma of critically ill patients can predict VAP 3 days before clinical symptoms occur, and we postulate that we will confirm the prognostic value of suPAR for mortality and ICU LOS. For this purpose, we performed a post hoc analysis of carefully defined VAP cases and matched controls recruited in the BioVAP study.

Methods

Study design and ethical approval

This was a post hoc study of the investigator-initiated observational, multicentre, prospective BioVAP (Biomarkers in the diagnosis and management of Ventilator-Associated Pneumonia) study, a study that ran in the ICUs of four university teaching hospitals [12]. BioVAP was registered at ClinicalTrials.gov (identifier NCT02078999), and the study protocol was approved by the institutional review boards and the local ethics committees of the four participating hospitals. Written informed consent was obtained from all patients or their legally authorised proxies.

Study population

Consecutive patients admitted to a participating ICU were screened for eligibility for recruitment over a 3-year period. Only the first ICU admission and the first VAP episode were included in the study. Patients were included when 1) they were on mechanical ventilation for >72 h, 2) there were no signs of pneumonia on the chest radiograph at admission, 3) they had not been receiving antibiotic treatment within 5 days prior to admission to the ICU, 4) expected duration of mechanical ventilation was >72 h and 5) no antibiotics were prescribed on admission by the responsible clinician (except for prophylactic purposes).

Exclusion criteria involved current or past participation in an intervention trial conflicting with the BioVAP study (e.g. studies into mechanical ventilation, antibiotic therapy or VAP prophylaxis), previous endotracheal intubation of >12 h within 30 days prior to recruitment, body mass index >40 kg·m−2, age <18 years, pregnancy, patients with known bronchiectasis, cystic fibrosis and/or witnessed pulmonary aspiration prior to or at intubation, and patients from whom informed consent was not obtained.

The control group consisted of ICU patients that were mechanically ventilated for >7 days, but did not develop VAP. This cut-off was selected because it corresponds to the median day of VAP development for the cases.

Primary and secondary end-points

The primary end-point was the diagnostic accuracy of suPAR for the diagnosis of VAP. The secondary end-points were the predictive accuracy of suPAR regarding mortality and ICU LOS.

Definition of VAP

VAP was defined as: a respiratory infection developing at least 48 h after the start of invasive mechanical ventilation in patients that had no signs of pneumonia at the time of tracheal intubation and without signs of pneumonia on their chest radiograph at admission to the ICU. The definition of VAP was based either on 1) clinical criteria (new or progressive pulmonary infiltrates on chest radiographs, together with at least two of the following: temperature >38°C or <36°C, white blood cell count >10 000 or <4000 mm−3, or purulent sputum) or 2) a simplified Clinical Pulmonary Infection Score (CPIS) ≥6 (after 48 h of mechanical ventilation) [21]. Pneumonia was microbiologically confirmed by the presence of at least one potentially pathogenic microorganism in respiratory samples above certain predefined thresholds: for BALF samples >104 CFU·mL−1 and for sputum or tracheobronchial aspirate samples >105 CFU·mL−1.

Follow-up

Follow-up of patients was established up until day 21 after ICU admission, the day of successful weaning and extubation, the day of an ICU-acquired infection other than VAP or the day of clinical diagnosis of VAP. Death, ICU discharge and hospital discharge were also assessed. A telephone interview was performed on day 90 after ICU admission in order to assess outcome.

Sample collection and measurements

Blood samples were obtained from an arterial line once daily from the time of ICU admission onwards and throughout the period of mechanical ventilation. suPAR was measured in the samples taken on the day of diagnosis, as well as in the samples taken 3 days before diagnosis. For the non-VAP patients (i.e. the control group) the samples were obtained in parallel: samples matched when they were collected after the same amount of days after exposure to the risk factor (i.e. start of mechanical ventilation).

The blood samples were collected using sterile Vacutainer tubes (BD, Franklin Lakes, NJ, USA) containing citrate and were centrifuged for 10 min at 4°C at 1800×g. suPAR detection was performed by ELISA using the suPARnostic kit provided by ViroGates (Birkerød, Denmark), which can determine suPAR concentrations as ng·mL−1 plasma.

A quantitative tracheal aspirate was obtained for all patients: the first sample was collected on ICU admission and subsequently twice a week (Mondays and Thursdays or Tuesdays and Fridays). These samples were used for microbiological confirmation of VAP.

Statistical analysis

Data are shown as median (interquartile range (IQR)). Plasma suPAR levels were compared between groups (patients who developed VAP versus those that did not develop VAP) using the nonparametric Mann–Whitney U-test. This was done for plasma suPAR measured at the time of diagnosis, as well as 3 days before diagnosis. For the control patients, matched samples were used that were collected after the same amount of days after the start of mechanical ventilation. The area under the receiver operating characteristic (ROC) curve (AUC) was used to assess the discriminative ability, sensitivity and specificity of suPAR levels: an AUC of 0.6–0.7 was considered as poor, 0.7–0.8 as fair, 0.8–0.9 as good and 0.9–1.0 as excellent. The default “DeLong method” in the roc.test function in R statistics was used to compare AUCs [22]. A p-value <0.05 was considered statistically significant. Linear regression was performed to assess the relation between hospital LOS and ICU LOS. Statistical analyses were performed in R statistics via the R-studio interface [23].

Results

Data and samples were collected from 43 patients (table 1); a flowchart detailing patient inclusion is shown in figure 1. VAP was microbiologically confirmed in 24 patients, which were considered cases; 19 noninfected patients served as controls. Simplified Acute Physiology Score II (SAPS II) [24] and Sepsis-related Organ Failure Assessment (SOFA) [25] scores were significantly higher between cases and controls. In addition, ICU LOS differed significantly in cases versus controls (p<0.001), as did the mortality rate (p=0.001).

View this table:
  • View inline
  • View popup
TABLE 1

Patient characteristics

FIGURE 1
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1

Flowchart of patient inclusion.

Microbiology of VAP

For the 24 VAP patients, a total of 27 isolates were distinguished in the respiratory samples: methicillin-susceptible Staphylococcus aureus (six patients), Haemophilus influenzae (four patients), Escherichia coli (three patients), Klebsiella pneumoniae (three patients), methicillin-resistant S. aureus (two patients), Pseudomonas aeruginosa (two patients), Citrobacter spp. (two patients), Streptococcus spp. (one patient), Acinetobacter baumannii (one patient), Moraxella catarrhalis (one patient), Proteus spp. (one patient) and Enterobacteriaceae spp. (one patient). The respiratory sample contained more than one pathogen in three cases.

Accuracy of suPAR levels for prediction of VAP 3 days before diagnosis

suPAR levels were significantly higher in the plasma of confirmed VAP patients (median (IQR) 6.2 (4.2–12.2) ng·mL−1) compared with controls (4.5 (3.5–5.9) ng·mL−1) when measured 3 days before diagnosis (AUC 0.68, 95% CI 0.52–1.00; p=0.04) (figure 2).

FIGURE 2
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2

Difference in soluble urokinase plasminogen activator receptor (suPAR) levels between diagnosed ventilator-associated pneumonia (VAP) patients and controls, measured 3 days before VAP diagnosis. Data are presented as box-and-whisker plots, with boxes showing the median (interquartile range (IQR)) and whiskers showing the range until maximum IQR. The scale on the y-axis has been log10 transformed.

When measured 3 days before diagnosis, the AUC for CPIS alone was 0.63 (95% CI 0.46–0.80; p=0.16). The combination of CPIS and suPAR led to an AUC of 0.68 (95% CI 0.52–0.84). The difference between the two ROC curves was not significant (p=0.54). The net reclassification improvement was 0.06 (or 6%; p=0.005), resulting in a higher specificity. CRP measured 3 days before diagnosis showed an AUC of 0.68 (95% CI 0.50–0.86; p=0.04). The combination of CRP and suPAR had an AUC of 0.74 (95% CI 0.56–0.92). The difference between these two AUCs was not significant (p=0.36). The net reclassification index (NRI) was 0.07 (7%; p=0.17), leading to an increased specificity. A weak positive correlation was found between suPAR and CRP, with a correlation coefficient of 0.21.

PCT had an AUC of 0.73 (95% CI 0.55–0.91; p=0.06) when measured 3 days before diagnosis. PCT combined with suPAR resulted in an AUC of 0.81 (95% CI 0.64–0.97). Again, the difference between the two AUCs was not significant (p=0.29). The NRI was 0.11 (11%; p<0.001), which led to a higher specificity. The combination of CRP, PCT and suPAR showed an AUC of 0.91 (95% CI 0.77–1.00). All AUCs are visualised in figure 3.

FIGURE 3
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3

Receiver operating characteristic curves for (combinations of) the Clinical Pulmonary Infection Score (CPIS), soluble urokinase plasminogen activator receptor (suPAR), C-reactive protein (CRP) and procalcitonin (PCT): measurements 3 days before ventilator-associated pneumonia diagnosis.

A correlation coefficient of 0.1 was found between suPAR and the SAPS II score at admission. SAPS II showed an AUC of 0.57 for diagnosing VAP (p=0.42). The combination of suPAR and SAPS II resulted in an AUC of 0.71 (95% CI 0.56–0.87). The difference between these two AUCs was not significant (p=0.18). The NRI was 0.09 (9%; p=0.002), accompanied by an increased specificity.

Accuracy of suPAR levels for the diagnosis of VAP

Also on the day of diagnosis, plasma suPAR levels were elevated in the VAP cases (AUC 0.77, 95% CI 0.6–0.93; p=0.01), with a median (IQR) of 6.6 (5.7–7.7) ng·mL−1 for the VAP patients versus 4.7 (3.6–6.3) ng·mL−1 for the controls (figure 4). In deceased patients the suPAR levels were significantly higher 3 days before diagnosis (AUC 0.79, 95% CI 0.57–1.00; p<0.001).

FIGURE 4
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4

Difference in soluble urokinase plasminogen activator receptor (suPAR) levels between diagnosed ventilator-associated pneumonia (VAP) patients and controls, measured on the day of VAP diagnosis. Data are presented as box-and-whisker plots, with boxes showing the median (interquartile range (IQR)) and whiskers showing the range until maximum IQR; outliers are represented by individual data points. The scale on the y-axis has been log10 transformed.

On the day of VAP diagnosis, the ROC for the CPIS alone had an AUC of 0.85 (95% CI 0.74–0.96; p=0.001). The AUC of the combination of CPIS plus plasma suPAR was 0.88 (95% CI 0.77–0.99). The difference between both AUCs was not significant (p=0.66). When testing this difference using the NRI, the net reclassification improvement was 0.07 (or 7%; p=0.005) when adding the suPAR values to the CPIS, increasing the sensitivity for predicting VAP.

CRP had an AUC of 0.64 (95% CI 0.47–0.8; p=0.09) when measured on the day of diagnosis. CRP combined with suPAR resulted in an AUC of 0.82 (95% CI 0.69–0.96). No significant difference (p=0.09) was seen between these two AUCs. The NRI was 0.14 (14%; p=0.003), leading to an increased sensitivity. A similarly weak positive correlation was found between suPAR and CRP when measured on the day of diagnosis, with a correlation coefficient of 0.23.

PCT showed an AUC of 0.71 (95% CI 0.55–0.87; p=0.15). The combination of PCT and suPAR had an AUC of 0.85 (95% CI 0.73–0.97). The difference between the two AUCs was not significant (p=0.19). An increased sensitivity was seen, with an NRI of 0.12 (12%; p=0.01). The combination of CRP, PCT and suPAR resulted in an AUC of 0.88 (95% CI 0.78–0.99) (figure 5).

FIGURE 5
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5

Receiver operating characteristic curves for (combinations of) the Clinical Pulmonary Infection Score (CPIS), soluble urokinase plasminogen activator receptor (suPAR), C-reactive protein (CRP) and procalcitonin (PCT): measurements on the day of ventilator-associated pneumonia diagnosis.

The SOFA score and suPAR level, both determined on the day of diagnosis, had a correlation coefficient of 0.15. The SOFA score could discriminate VAP cases from controls with an AUC of 0.83 (95% CI 0.71–0.95; p=0.003). suPAR combined with the SOFA score led to an AUC of 0.88 (95% CI 0.78–0.98). The NRI was 0.07 (7%; p=0.02), resulting in a higher sensitivity.

Predictive accuracy

Plasma suPAR levels appeared to be significantly different between alive and deceased patients, both when measured 3 days before diagnosis (p=0.005) and on the day of diagnosis (p=0.04) (figure 6).

FIGURE 6
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6

Difference in soluble urokinase plasminogen activator receptor (suPAR) levels between alive and deceased patients, measured 3 days before ventilator-associated pneumonia diagnosis. Data are presented as box-and-whisker plots, with boxes showing the median (interquartile range (IQR)) and whiskers showing the range until maximum IQR; outliers are represented by individual data points. The scale on the y-axis has been log10 transformed.

Figure 7 shows the association between measured plasma suPAR levels and ICU LOS, showing an OR of 1.43 (p=0.02). The association between plasma suPAR and hospital LOS appeared not to be significant (OR 1.0; p=0.99).

FIGURE 7
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 7

Scatterplot showing the association between plasma soluble urokinase plasminogen activator receptor (suPAR) levels and intensive care unit (ICU) length of stay.

Discussion

Based on the results from this study we conclude that plasma suPAR levels are elevated 3 days before the diagnosis of VAP and have a moderate predictive accuracy. Classification improves when combined with CPIS, CRP and PCT. The diagnostic accuracy was also moderate and does not seem to be sufficient to justify further evaluation. We confirmed moderate prognostic accuracy of suPAR in critically ill ICU patients.

Our data suggest that a plasma biomarker may have limited value when used by itself, but its performance can increase substantially when added to a clinical scoring system. In general, biomarkers can be used for diagnostic purposes, response prediction or therapeutic monitoring [26]. The relevance of plasma suPAR may be in its additive predictive value on top of clinical judgement and/or in addition to a scoring system like CPIS, or when used in conjunction with other biomarkers [27]. PCT has been investigated extensively regarding its value to be used as a biomarker to guide antibiotic stewardship [28–32]. As yet, PCT seems to have a poor predictive performance for VAP [12]. Furthermore, the utility of CRP as a marker for VAP has not yet been demonstrated either [33]. Nevertheless, CRP has been used for indication of emerging VAP infection [34] and was used to monitor response to antibiotic treatment in VAP patients [12].

Irrespective of initiation of the appropriate treatment, suPAR remains stable in the systemic circulation of survivors as well as nonsurvivors within the first 10 days of the disease course [19]. The elevated plasma suPAR concentration remains robust for days to weeks, with a half-life of >7–10 days [35]. Our results are in accordance with those findings: hardly any change was seen between the suPAR concentration 3 days before and on the day of VAP diagnosis, neither for the VAP patients nor for the control group. As a result, plasma suPAR seems ineligible to evaluate therapy response [36] or guide antibiotic stewardship in VAP. Nevertheless, it could serve as a good early predictor for the disease and thus should be regarded as an extra indicator to distinguish patients at risk of developing VAP.

Serum suPAR has been shown to be associated with disease severity (ICU admission and/or mortality) in patients with community-acquired pneumonia [37, 38] and VAP [20]. suPAR levels also seemed to be important as a possible predictor of mortality in systemic inflammatory response syndrome [39]. In our cohort, plasma suPAR levels, when measured 3 days before VAP diagnosis, appeared to have a fair predictive value for mortality in critically ill patients. While there was no association between suPAR and hospital LOS, suPAR levels showed a good correlation with ICU LOS. As the plasma concentration of suPAR reflects immune activation, a recent meta-analysis assessed the usefulness of suPAR for the prognosis of bacterial infections [40]. After pooling the data, a fair performance was found for suPAR in terms of mortality prediction, with an AUC of 0.77. Regarding the potential of suPAR for diagnosing infection, the same meta-analysis found a pooled sensitivity and specificity of 0.73 and 0.79, respectively, accompanied by an AUC of 0.82 [40]. An earlier study investigating the diagnostic potential of suPAR for diagnosing VAP reported AUCs of 0.45 for suPAR levels on the first day of mechanical ventilation and 0.25 for suPAR levels within 24 h after VAP diagnosis [27]. The discrepancy between those results and the AUCs found in our study might be explained in part by the different composition of the control groups. The control group in the study by Sunnetcioglu et al. [27] consisted of non-VAP patients that were matched based on age and sex, whereas the control group in our study consisted of non-VAP patients who were matched based on days of mechanical ventilation.

Within the pathophysiology of pneumonia, Gram-negative or Gram-positive bacteria induce upregulated expression of uPAR (from which suPAR is derived) on monocytes and neutrophils, contributing to the host defence against pulmonary infection, especially demonstrated for respiratory infections caused by P. aeruginosa [41]. Reduced neutrophil migration and impaired phagocytosis in the lungs have been shown to occur in uPAR knockout mice; thus, patients with an impaired suPAR system may show a decreased effect of the neutrophil-mediated bactericide reaction [42]. Due to this potential affinity of suPAR with pulmonary processes in particular, it might be specifically interesting (according to our study results) to add suPAR to currently available clinical biomarkers like CRP and PCT or clinical scoring systems like CPIS and SOFA.

Our study investigated the use of suPAR concentrations measured in blood plasma. Alternatively, suPAR can be determined in various other body fluids, e.g. in urine, cerebrospinal fluid or cystic fluid. When measured locally in pleural effusion fluid, suPAR has been shown to be potentially useful for exclusion of infection in ICU patients [43]. suPAR concentrations detected in saliva appeared not to be correlated to suPAR levels in simultaneously obtained plasma samples [44], indicating that care should be taken when directly comparing suPAR values acquired by analysis of fluid samples of different origin.

The strength of this study is in the multicentre and prospective nature of its design, collecting data for 6 days from all noninfected patients that were mechanically ventilated for >72 h. Limitations include the small sample size of only 43 patients and the absence of a validation cohort. Another limitation is the absence of available suPAR values in patients who were (in part) clinically suspicious for VAP but who had VAP negative or subthreshold microbiology results, since suPAR was only measured in patients who had positive endotracheal aspirate results. However, we could argue that the CPIS captures this clinical suspicion of VAP in a composite of clinical variables and we have been able to show the additive value of suPAR to this clinical score. In addition, the absence of a clinically available gold standard for VAP diagnosis is an important limitation of the study: microbiological examination of BALF is currently the best available reference standard and is, as such, widely accepted by the research community. Future studies into the function of plasma suPAR as a diagnostic biomarker for VAP should use an independent cohort to validate our aforementioned findings.

To conclude, suPAR can be used to diagnose VAP with a fair diagnostic accuracy and has a moderate prognostic accuracy to be used in critically ill ICU patients. Its performance improves when added to other clinically available biomarkers (CRP and PCT) or scoring systems (CPIS and SOFA).

Footnotes

  • Conflict of interest: P.M. van Oort has nothing to disclose.

  • Conflict of interest: L.D. Bos has nothing to disclose.

  • Conflict of interest: P. Póvoa reports grants from Thermo Fisher Scientific during the conduct of the study.

  • Conflict of interest: P. Ramirez has nothing to disclose.

  • Conflict of interest: A. Torres reports lectures for Brahms during the conduct of the study.

  • Conflict of interest: A. Artigas reports grants from and speaking at a symposium for Thermo Fisher Scientific during the conduct of the study.

  • Conflict of interest: M.J. Schultz has nothing to disclose.

  • Conflict of interest: I. Martin-Loeches has nothing to disclose.

  • Received November 12, 2018.
  • Accepted January 31, 2019.
  • Copyright ©ERS 2019
http://creativecommons.org/licenses/by-nc/4.0/

This article is open access and distributed under the terms of the Creative Commons Attribution Non-Commercial Licence 4.0.

References

  1. ↵
    1. Torres A,
    2. Niederman MS,
    3. Chastre J, et al.
    International ERS/ESICM/ESCMID/ALAT guidelines for the management of hospital-acquired pneumonia and ventilator-associated pneumonia. Eur Respir J 2017; 50: 1700582.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    1. Warren DK,
    2. Shukla SJ,
    3. Olsen MA, et al.
    Outcome and attributable cost of ventilator-associated pneumonia among intensive care unit patients in a suburban medical center. Crit Care Med 2003; 31: 1312–1317.
    OpenUrlCrossRefPubMed
  3. ↵
    1. Melsen W,
    2. Rovers M,
    3. Groenwold R, et al.
    Attributable mortality of ventilator-associated pneumonia: a meta-analysis of individual patient data from randomised prevention studies. Lancet Infect Dis 2013; 13: 665–671.
    OpenUrlCrossRefPubMed
  4. ↵
    1. Martin-Loeches I,
    2. Bos LD,
    3. Povoa P, et al.
    Tumor necrosis factor receptor 1 (TNFRI) for ventilator-associated pneumonia diagnosis by cytokine multiplex analysis. Intensive Care Med Exp 2015; 3: 26.
    OpenUrl
  5. ↵
    1. Browne E,
    2. Hellyer TP,
    3. Baudouin S V, et al.
    A national survey of the diagnosis and management of suspected ventilator-associated pneumonia. BMJ Open Respir Res 2014; 1: e000066.
    OpenUrlAbstract/FREE Full Text
  6. ↵
    1. Martin-Loeches I,
    2. Povoa P,
    3. Rodríguez A, et al.
    Incidence and prognosis of ventilator-associated tracheobronchitis (TAVeM): a multicentre, prospective, observational study. Lancet Respir Med 2015; 3: 859–868.
    OpenUrl
  7. ↵
    1. Chastre J,
    2. Fagon J
    . State of the art ventilator-associated pneumonia. Am J Respir Crit Care Med 2002; 165: 867–903.
    OpenUrlCrossRefPubMed
  8. ↵
    1. Gibot S,
    2. Cravoisy A,
    3. Levy B, et al.
    Soluble triggering receptor expressed on myeloid cells and the diagnosis of pneumonia. N Engl J Med 2004; 350: 451–458.
    OpenUrlCrossRefPubMed
  9. ↵
    1. Conway Morris A,
    2. Kefala K,
    3. Wilkinson TS, et al.
    Diagnostic importance of pulmonary interleukin-1β and interleukin-8 in ventilator-associated pneumonia. Thorax 2010; 65: 201–207.
    OpenUrlAbstract/FREE Full Text
    1. Hellyer TP,
    2. Morris AC,
    3. McAuley DF, et al.
    Diagnostic accuracy of pulmonary host inflammatory mediators in the exclusion of ventilator-acquired pneumonia. Thorax 2014; 70: 41–47.
    OpenUrl
  10. ↵
    1. Hellyer TP,
    2. Anderson NH,
    3. Parker J, et al.
    Effectiveness of biomarker-based exclusion of ventilator-acquired pneumonia to reduce antibiotic use (VAPrapid-2): study protocol for a randomised controlled trial. Trials 2016; 17: 318.
    OpenUrl
  11. ↵
    1. Póvoa P,
    2. Martin-Loeches I,
    3. Ramirez P, et al.
    Biomarker kinetics in the prediction of VAP diagnosis: results from the BioVAP study. Ann Intensive Care 2016; 6: 32.
    OpenUrl
  12. ↵
    1. Luyt CE,
    2. Combes A,
    3. Reynaud C, et al.
    Usefulness of procalcitonin for the diagnosis of ventilator-associated pneumonia. Intensive Care Med 2008; 34: 1434–1440.
    OpenUrlCrossRefPubMed
  13. ↵
    1. Backes Y,
    2. Van Der Sluijs KF,
    3. Mackie DP, et al.
    Usefulness of suPAR as a biological marker in patients with systemic inflammation or infection: a systematic review. Intensive Care Med 2012; 38: 1418–1428.
    OpenUrlCrossRefPubMed
  14. ↵
    1. Jalkanen V,
    2. Yang R,
    3. Linko R, et al.
    SuPAR and PAI-1 in critically ill, mechanically ventilated patients. Intensive Care Med 2013; 39: 489–496.
    OpenUrlCrossRefPubMed
  15. ↵
    1. Geboers DGPJ,
    2. de Beer FM,
    3. de Boer AMT, et al.
    Plasma suPAR as a prognostic biological marker for ICU mortality in ARDS patients. Intensive Care Med 2015; 41: 1281–1290.
    OpenUrl
  16. ↵
    1. Backes Y,
    2. van der Sluijs KF,
    3. de Boer AM T, et al.
    Soluble urokinase-type plasminogen activator receptor levels in patients with burn injuries and inhalation trauma requiring mechanical ventilation: an observational cohort study. Crit Care 2011; 15: R270.
    OpenUrlCrossRefPubMed
  17. ↵
    1. Rasmussen LJH,
    2. Ladelund S,
    3. Haupt TH, et al.
    Soluble urokinase plasminogen activator receptor (suPAR) in acute care: a strong marker of disease presence and severity, readmission and mortality. A retrospective cohort study. Emerg Med J 2016; 33: 769–775.
    OpenUrlAbstract/FREE Full Text
  18. ↵
    1. Koch A,
    2. Voigt S,
    3. Kruschinski C, et al.
    Circulating soluble urokinase plasminogen activator receptor is stably elevated during the first week of treatment in the intensive care unit and predicts mortality in critically ill patients. Crit Care 2011; 15: R63.
    OpenUrlCrossRefPubMed
  19. ↵
    1. Savva A,
    2. Raftogiannis M,
    3. Baziaka F, et al.
    Soluble urokinase plasminogen activator receptor (suPAR) for assessment of disease severity in ventilator-associated pneumonia and sepsis. J Infect 2011; 63: 344–350.
    OpenUrlCrossRefPubMed
  20. ↵
    1. Pugin J,
    2. Auckenthaler R,
    3. Mili N, et al.
    Diagnosis of ventilator-associated pneumonia by bacteriologic analysis of bronchoscopic and nonbronchoscopic “blind” bronchoalveolar lavage fluid. Am Rev Respir Dis 1991; 143: 1121–1129.
    OpenUrlCrossRefPubMed
  21. ↵
    1. DeLong ER,
    2. DeLong DM,
    3. Clarke-Pearson DL
    . Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988; 44: 837–845.
    OpenUrlCrossRefPubMed
  22. ↵
    R Development Core Team. R: A Language and Environment for Statistical Computing. Vienna, R Foundation for Statistical Computing, 2010.
  23. ↵
    1. Le Gall J,
    2. Lemeshow S,
    3. Saulnier F
    . A new Simplified Acute Physiology Score (SAPS II) based on a European/North American multicenter study. JAMA 1993; 270: 2957–2963.
    OpenUrlCrossRefPubMed
  24. ↵
    1. Vincent J-L,
    2. Moreno R,
    3. Takala J, et al.
    The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction/failure. Intensive Care Med 1996; 22: 707–710.
    OpenUrlCrossRefPubMed
  25. ↵
    1. Selleck MJ,
    2. Senthil M,
    3. Wall NR
    . Making meaningful clinical use of biomarkers. Biomark Insights 2017; 12: 1177271917715236.
    OpenUrl
  26. ↵
    1. Sunnetcioglu A,
    2. Sunnetcioglu M,
    3. Adıyaman F, et al.
    Could soluble urokinase plasminogen receptor (suPAR) be used as a diagnostic biomarker for ventilator-associated pneumonia? Clin Respir J 2017; 11: 925–930.
    OpenUrl
  27. ↵
    1. de Jong E,
    2. van Oers JA,
    3. Beishuizen A, et al.
    Efficacy and safety of procalcitonin guidance in reducing the duration of antibiotic treatment in critically ill patients: a randomised, controlled, open-label trial. Lancet Infect Dis 2016; 16: 819–827.
    OpenUrlCrossRef
    1. Bloos F,
    2. Trips E,
    3. Nierhaus A, et al.
    Effect of sodium selenite administration and procalcitonin-guided therapy on mortality in patients with severe sepsis or septic shock. JAMA Intern Med 2016; 176: 1266–1276.
    OpenUrl
    1. Chu DC,
    2. Mehta AB,
    3. Walkey AJ
    . Practice patterns and outcomes associated with procalcitonin use in critically ill patients with sepsis. Clin Infect Dis 2017; 64: 1509–1515.
    OpenUrl
    1. Huang DT,
    2. Yealy DM,
    3. Filbin MR, et al.
    Procalcitonin-guided use of antibiotics for lower respiratory tract infection. N Engl J Med 2018; 379: 236–249.
    OpenUrlCrossRefPubMed
  28. ↵
    1. Daubin C,
    2. Valette X,
    3. Thiollière F, et al.
    Procalcitonin algorithm to guide initial antibiotic therapy in acute exacerbations of COPD admitted to the ICU: a randomized multicenter study. Intensive Care Med 2018; 44: 428–437.
    OpenUrl
  29. ↵
    1. Palazzo SJ,
    2. Simpson T,
    3. Schnapp L
    . Biomarkers for ventilator-associated pneumonia: review of the literature. Hear Lung J Acute Crit Care 2011; 40: 293–298.
    OpenUrl
  30. ↵
    1. Filipiak W,
    2. Beer R,
    3. Sponring A, et al.
    Breath analysis for in vivo detection of pathogens related to ventilator-associated pneumonia in intensive care patients: a prospective pilot study. J Breath Res 2015; 9: 016004.
    OpenUrlCrossRefPubMed
  31. ↵
    1. Huttunen R,
    2. Syrjänen J,
    3. Vuento R, et al.
    Plasma level of soluble urokinase-type plasminogen activator receptor as a predictor of disease severity and case fatality in patients with bacteraemia: a prospective cohort study. J Intern Med 2011; 270: 32–40.
    OpenUrlCrossRefPubMed
  32. ↵
    1. Donadello K,
    2. Scolletta S,
    3. Taccone FS, et al.
    Soluble urokinase-type plasminogen activator receptor as a prognostic biomarker in critically ill patients. J Crit Care 2014; 29: 144–149.
    OpenUrlPubMed
  33. ↵
    1. Loonen AJM,
    2. Kesarsing C,
    3. Kusters R, et al.
    High pneumococcal DNA load, procalcitonin and suPAR levels correlate to severe disease development in patients with pneumococcal pneumonia. Eur J Clin Microbiol Infect Dis 2017; 36: 1541–1547.
    OpenUrl
  34. ↵
    1. Luo Q,
    2. Ning P,
    3. Zheng Y, et al.
    Serum suPAR and syndecan-4 levels predict severity of community-acquired pneumonia: a prospective, multi-centre study. Crit Care 2018; 22: 1–12.
    OpenUrl
  35. ↵
    1. Yilmaz G,
    2. Köksal I,
    3. Karahan SC, et al.
    The diagnostic and prognostic significance of soluble urokinase plasminogen activator receptor in systemic inflammatory response syndrome. Clin Biochem 2011; 44: 1227–1230.
    OpenUrlCrossRefPubMed
  36. ↵
    1. Ni W,
    2. Han Y,
    3. Zhao J, et al.
    Serum soluble urokinase-type plasminogen activator receptor as a biological marker of bacterial infection in adults: a systematic review and meta-analysis. Sci Rep 2016; 6: 39481.
    OpenUrl
  37. ↵
    1. Rijneveld AW,
    2. Levi M,
    3. Florquin S, et al.
    urokinase receptor is necessary for adequate host defense against pneumococcal pneumonia. J Immunol 2002; 168: 3507–3511.
    OpenUrlAbstract/FREE Full Text
  38. ↵
    1. Wrotek A,
    2. Jackowska T,
    3. Pawlik K
    . Soluble urokinase plasminogen activator receptor: an indicator of pneumonia severity in children. Adv Exp Med Biol 2015; 835: 1–7.
    OpenUrl
  39. ↵
    1. Bakker OGM,
    2. Hemmes SNT,
    3. Backes Y, et al.
    SuPAR in pleural fluid may function as a biological marker for infection in critically ill patients with pleural effusions. J Infect 2014; 68: 607–609.
    OpenUrl
  40. ↵
    1. Gustafsson A,
    2. Ajeti V,
    3. Ljunggren L
    . Detection of suPAR in the saliva of healthy young adults: comparison with plasma levels. Biomark Insights 2011; 6: 119–125.
    OpenUrlPubMed
PreviousNext
Back to top
Vol 5 Issue 1 Table of Contents
ERJ Open Research: 5 (1)
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Soluble urokinase plasminogen activator receptor for the prediction of ventilator-associated pneumonia
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Soluble urokinase plasminogen activator receptor for the prediction of ventilator-associated pneumonia
Pouline M. van Oort, Lieuwe D. Bos, Pedro Póvoa, Paula Ramirez, Antoni Torres, Antonio Artigas, Marcus J. Schultz, Ignacio Martin-Loeches
ERJ Open Research Feb 2019, 5 (1) 00212-2018; DOI: 10.1183/23120541.00212-2018

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Soluble urokinase plasminogen activator receptor for the prediction of ventilator-associated pneumonia
Pouline M. van Oort, Lieuwe D. Bos, Pedro Póvoa, Paula Ramirez, Antoni Torres, Antonio Artigas, Marcus J. Schultz, Ignacio Martin-Loeches
ERJ Open Research Feb 2019, 5 (1) 00212-2018; DOI: 10.1183/23120541.00212-2018
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Abstract
    • Introduction
    • Methods
    • Results
    • Discussion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Subjects

  • Respiratory infections and tuberculosis
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

Original articles

  • Endobronchial autologous BM-MSCs in IPF patients
  • Effect of β-blockers on the risk of COPD exacerbations
  • Recurrence of symptoms after childhood LRTI
Show more Original articles

Respiratory infections

  • High pneumonia incidence among young men
  • Multiplex bacterial PCR in BALF
  • Pseudomonas aeruginosa in adult long-term ventilation
Show more Respiratory infections

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About ERJ Open Research

  • Editorial board
  • Journal information
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Online ISSN: 2312-0541

Copyright © 2023 by the European Respiratory Society