TABLE 2

Within-patient absolute agreement between tremoFlo and MasterScreen impulse oscillometry system (IOS) values

Patients ntremoFlo kPa·L−1·s−1IOS kPa·L−1·s−1tremoFlo versus IOS ICC (95% CI)
Mean±sdMedian (IQR)Mean±sdMedian (IQR)
Resistance#
R5380.80±0.350.71 (0.34)0.82±0.310.72 (0.34)0.91 (0.83–0.95)
R10380.74±0.300.67 (0.28)0.66±0.210.60 (0.26)0.91 (0.82–0.95)
R15380.63±0.250.57 (0.25)0.60±0.170.54 (0.22)0.90 (0.80–0.95)
R20380.59±0.220.53 (0.26)0.56±0.150.52 (0.19)0.88 (0.77–0.94)
R25380.56±0.200.51 (0.24)0.55±0.150.51 (0.21)0.91 (0.82–0.95)
R5–20380.21±0.180.18 (0.17)0.26±0.210.23 (0.19)0.83 (0.68–0.91)
Reactance#
X538−0.36±0.20−0.31 (0.16)−0.19±0.14−0.18 (0.14)0.75 (0.52–0.87)
X1038−0.18±0.17−0.13 (0.16)−0.16±0.13−0.14 (0.15)0.82 (0.66–0.91)
X1538−0.17±0.16−0.12 (0.12)−0.10±0.11−0.09 (0.14)0.87 (0.76–0.93)
X2038−0.09±0.14−0.06 (0.11)−0.02±0.08−0.01 (0.09)0.78 (0.58–0.89)
X25380.002±0.1230.02 (0.12)0.06±0.060.05 (0.09)0.69 (0.40–0.84)
X5–2038−0.27±0.09−0.25 (0.09)−0.17±0.13−0.19 (0.17)0.70 (0.42–0.84)
AX383.25±2.922.40 (2.31)
Fres+2619.64±4.5921.67 (6.01)18.46±3.6519.25 (3.86)0.63 (0.38–0.82)

IQR: interquartile range; ICC: intraclass correlation coefficient; AX: area under the curve for resistance; Fres: resonant frequency. #: R represents resistance and X represents reactance at various oscillatory frequencies, including the frequency dependency between R or X parameters measured at 5–20 Hz; : only available on the tremoFlo, such that no agreement was examined with the IOS; +: reported only for patients in whom it was ≤25 Hz, to avoid extrapolation of data.