TABLE 2

Haemodynamics during mechanical ventilation in nonsmall cell lung cancer (MV-NSCLC) and mechanical ventilation in the control group (MV-C)

ParametersMV-NSCLCMV-C
StartStopp-valueStartStopp-value
BP systolic mmHg106±3104±20.65102±5104±20.87
BP diastolic mmHg59±257±10.2459±359±20.98
MAP mmHg76±273±10.2375±376±30.78
Pulse76±371±40.4178±474±40.41
EtCO2 kPa5.1±0.14.7±0.10.115.3±0.24.8±0.20.14
Saturation %99±199±10.1599±199±10.1
Respiration frequency15±116±10.6116±117±10.84
VT inspiration mL453±15470±130.43437±27418±270.65
VT expiration mL440±14453±150.56420±26404±320.72
Peak pressure cmH2O15±119±10.0115±117±10.32
Air leakage mL13±221±10.3116±414±70.79

Data are presented as mean±sem, unless otherwise stated. BP: blood pressure; MAP: mean arterial pressure; EtCO2: end tidal carbon dioxide; VT: tidal volume.