TABLE 2

Differences in walking distance and oxygen saturation between the two experimental conditions

Outcome6MWTwith6MWTwithoutMean differencep-value
6MWT m337.8±85.7346.5±86.4−9.1 (−13.9–−4.3)0.0004
SpO2 nadir %85.1±5.485.0±5.60.06 (−0.49–0.62)0.82
SpO2 artefact n17 (4–24)11 (3­–26)0.60 (−3.76–4.96)0.78
SpO2 artefact s34 (7–113)24 (4–62)17.90 (−5.45–41.20)0.13

Data are given as mean±sd or median (interquartile range). Mean differences (95% CI) between 6 MWTwith versus 6MWTwithout and SpO2 outcomes were analysed with a linear regression model adjusting for the experimental condition, period and subject. 6MWT: 6-min walk test; 6MWTwith: assessor walking behind the patient during 6MWT; 6MWTwithout: patient walking alone during 6MWT; SpO2: peripheral oxygen saturation.