Diagnosis of pulmonary embolism based upon alveolar dead space analysis

Chest. 1989 Aug;96(2):357-62. doi: 10.1378/chest.96.2.357.

Abstract

Pulmonary embolism (PE) leads to an abnormal alveolar deadspace that is expired in synchrony with gas from normally perfused alveoli. This feature of PE separates it from pulmonary diseases affecting the airways, which are characterized by nonsynchronous emptying of compartments with an uneven ventilation/perfusion relationship. An analysis of the single breath test (SBT) for CO2, SBT-CO2, focusing on the late tidal expirate, was made in order to evaluate the feasibility to use the SBT-CO2 for the diagnosis of PE. The test was evaluated in 38 patients with suspected PE where pulmonary angiography showed that nine had PE and 29 did not. It was also tested in a reference population consisting of patients with normal lung function, obstructive lung disease and interstitial lung disease. Previously suggested gas exchange measurements for the diagnosis of PE, ie, the physiologic deadspace fraction, VDphys/VT, and the arterial-to-end-tidal CO2 gradient, P(a-E')CO2, were also evaluated in the groups. SBT-CO2 achieved a nearly complete separation between the patients with PE and those without. The other measurements, however, showed a substantial overlap between patients with PE and those with obstructive or interstitial lung disease. The SBT-CO2 is simple and potentially widely available and warrants further study as a routine technique for the diagnosis of PE.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Angiography
  • Female
  • Humans
  • Lung Diseases, Obstructive / diagnosis
  • Lung Volume Measurements
  • Male
  • Middle Aged
  • Pulmonary Alveoli / physiopathology
  • Pulmonary Artery / diagnostic imaging
  • Pulmonary Embolism / diagnosis*
  • Pulmonary Fibrosis / diagnosis
  • Pulmonary Gas Exchange
  • Reference Values
  • Respiratory Dead Space*